All TopicsFlow

Flow Instrument Simulator – Interactive Flow Measurement

How Flow Transmitters Measure Flow

There is no single way to measure flow. Some meters measure a pressure drop, some spin or shake, some use magnets, sound, heat or radar. Pick a flow transmitter, change the flow, then change the fluid and the installation to find out where each type works well and where it fails.

From flow to 4-20 mA (signal chain)

Sensor signal, conditioning electronics, ADC, microprocessor (linearises, corrects and converts to flow), then the 4-20 mA output. If there is no usable signal the transmitter goes to a fail-safe 3.6 mA.

How it works

    About this flow meter type

    What it measures
    Typical accuracy
    Best for
    Weak point
    Straight pipe needed upstream
    Response time constant

    1Choose a flow meter type

    2Change the flow

    m3/h
    The pipe is 100 mm (DN100). 100 m3/h in this pipe is a velocity of about 3.5 m/s.

    3Fluid and installation

    Pipe length is given in pipe diameters (D). Bends and valves upstream disturb the flow profile, which spoils some meters. The fluid decides which meters can work at all.

    Transmitter readings

    True flow
    Velocity and Reynolds number
    Sensor raw signal
    Digital value (16-bit)
    Flow read by transmitter
    Measurement error
    Output (% of span) and current
    Suitability for this fluid

    Response to a flow change

    grey dashed = true flow, blue = what the transmitter reads. Last 60 s.

    Sensor signal vs flow

    x: flow (% of range), y: raw sensor signal (% of its full-scale change). Orange dashed = a perfect straight line. A curved line (DP: square law, radar: level to the 2/3 power, thermal: square root) must be corrected by the microprocessor.

    Compare all flow meter types

    Fluid columns: \u25CF works well, \u25B2 poor or limited, \u2715 does not work.

    Explore an interactive Flow Instrument Simulator to understand how industrial flow meters measure liquid and gas flow. Compare different technologies, including differential pressure, rotameter, turbine, positive displacement, vortex, electromagnetic, ultrasonic, Coriolis, thermal mass, and open-channel flow measurement.

    Adjust flow rate, fluid type, straight-pipe length, and air bubbles to observe changes in sensor signals, measurement accuracy, and transmitter output. Learn how flow velocity, Reynolds number, density, viscosity, and fluid conductivity affect measurement performance.